Djupetjønn

Hydrological station 36.20.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-21T00:32:54Z.

Station and available series

stationId:
36.20.0
stationName:
Djupetjønn
latitude:
59.76307
longitude:
6.99984
utmEast_Z33:
51305
utmNorth_Z33:
6652156
masl:
1161
riverName:
Stølsåna
councilNumber:
1134
councilName:
Suldal
countyName:
Rogaland
drainageBasinKey:
1021
hierarchy:
Stølsåna/Suldalsvassdraget
lakeArea:
0.59
lakeName:
Djupetjørn
lakeNo:
1868
regineNo:
036.CH
reservoirNo:
580
reservoirName:
DJUPETJØNN
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
6.02
drainageBasinAreaNorway:
6.016
gradient1085:
26.87
gradientBasin:
26.21
gradientRiver:
29.78
heightMinimum:
1167
heightHypso10:
1193
heightHypso20:
1220
heightHypso30:
1248
heightHypso40:
1267
heightHypso50:
1283
heightHypso60:
1317
heightHypso70:
1356
heightHypso80:
1373
heightHypso90:
1445
heightMaximum:
1556
lengthKmBasin:
2.95
lengthKmRiver:
3.32
percentAgricul:
0
percentBog:
0
percentEffBog:
not reported by source
percentEffLake:
9.24
percentForest:
0
percentGlacier:
0
percentLake:
12.44
percentMountain:
87.58
percentUrban:
0
utmZoneGravi:
33
utmEastGravi:
51977
utmNorthGravi:
6652630
utmZoneInlet:
33
utmEastInlet:
52844
utmNorthInlet:
6654447
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
14.75
specificDischarge:
78.29
regulationArea:
5.97
areaReservoirs:
0.59
volumeReservoirs:
7.5
regulationPartReservoirs:
0.51
transferAreaIn:
1.86
transferAreaOut:
0
reservoirAreaIn:
0.42
reservoirAreaOut:
0.59
reservoirVolumeIn:
0
reservoirVolumeOut:
7.5
remainingArea:
0
numberReservoirs:
1
firstYearRegulation:
1967
catchmentRegTypeName:
Regulert m/magasinregulering og overføringer
owner:
Hydro Energi Røldal-Suldal
qNumberOfYears:
not reported by source
qStartYear:
not reported by source
qEndYear:
not reported by source
qm:
not reported by source
q5:
not reported by source
q10:
not reported by source
q20:
not reported by source
q50:
not reported by source
hm:
not reported by source
h5:
not reported by source
h10:
not reported by source
h20:
not reported by source
h50:
not reported by source
culQm:
not reported by source
culQ5:
not reported by source
culQ10:
not reported by source
culQ20:
not reported by source
culQ50:
not reported by source
culHm:
not reported by source
culH5:
not reported by source
culH10:
not reported by source
culH20:
not reported by source
culH50:
not reported by source
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    0
    unit:
    m
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    2 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1975-01-01T11:00:00Z
      dataToTime:
      2026-06-12T23:00:00Z
    2. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1975-01-01T11:00:00Z
      dataToTime:
      2026-06-13T11:00:00Z
  2. parameterName:
    Magasinvolum
    parameter:
    1004
    versionNo:
    0
    unit:
    millioner m³
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    2 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1975-01-01T11:00:00Z
      dataToTime:
      2026-06-12T23:00:00Z
    2. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1975-01-01T11:00:00Z
      dataToTime:
      2026-06-13T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.