Teksevatn

Hydrological station 27.19.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-22T12:01:18Z.

Station and available series

stationId:
27.19.0
stationName:
Teksevatn
latitude:
58.55184
longitude:
6.24367
utmEast_Z33:
-8684
utmNorth_Z33:
6523412
masl:
182
riverName:
Tekseåni
councilNumber:
1101
councilName:
Eigersund
countyName:
Rogaland
drainageBasinKey:
934
hierarchy:
Tekseåni/Hellelandselva
lakeArea:
1.92
lakeName:
Teksevatnet
lakeNo:
1541
regineNo:
027.3CB
reservoirNo:
434
reservoirName:
TEKSEVATN
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
51.98
drainageBasinAreaNorway:
51.98
gradient1085:
11.13
gradientBasin:
31.1
gradientRiver:
21.51
heightMinimum:
179
heightHypso10:
197
heightHypso20:
212
heightHypso30:
239
heightHypso40:
346
heightHypso50:
407
heightHypso60:
483
heightHypso70:
529
heightHypso80:
568
heightHypso90:
623
heightMaximum:
732
lengthKmBasin:
12.28
lengthKmRiver:
14.74
percentAgricul:
7.62
percentBog:
0.34
percentEffBog:
not reported by source
percentEffLake:
6.08
percentForest:
23.64
percentGlacier:
0
percentLake:
13.26
percentMountain:
32.67
percentUrban:
0.08
utmZoneGravi:
33
utmEastGravi:
-2762
utmNorthGravi:
6522642
utmZoneInlet:
33
utmEastInlet:
-3605
utmNorthInlet:
6525779
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
111.33
specificDischarge:
67.91
regulationArea:
51.96
areaReservoirs:
4.1
volumeReservoirs:
22.7
regulationPartReservoirs:
0.2
transferAreaIn:
0
transferAreaOut:
0
reservoirAreaIn:
0
reservoirAreaOut:
0
reservoirVolumeIn:
0
reservoirVolumeOut:
0
remainingArea:
-0.01
numberReservoirs:
3
firstYearRegulation:
1969
catchmentRegTypeName:
regulert m/magasinregulering
owner:
DALANE ENERGI IKS
qNumberOfYears:
90
qStartYear:
1926
qEndYear:
2015
qm:
not reported by source
q5:
not reported by source
q10:
not reported by source
q20:
not reported by source
q50:
not reported by source
hm:
182.3499
h5:
182.4544
h10:
182.6014
h20:
182.7749
h50:
183.059
culQm:
not reported by source
culQ5:
not reported by source
culQ10:
not reported by source
culQ20:
not reported by source
culQ50:
not reported by source
culHm:
182.3499
culH5:
182.4544
culH10:
182.6014
culH20:
182.7749
culH50:
183.059
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    1
    unit:
    m
    serieFrom:
    1925-07-08T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1925-07-08T11:00:00Z
      dataToTime:
      2026-09-22T11:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2015-08-25T01:00:00Z
      dataToTime:
      2026-09-22T11:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1925-07-08T11:00:00Z
      dataToTime:
      2026-09-21T11:00:00Z
  2. parameterName:
    Magasinvolum
    parameter:
    1004
    versionNo:
    1
    unit:
    millioner m³
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1925-07-08T11:00:00Z
      dataToTime:
      2026-09-22T11:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2015-08-25T01:00:00Z
      dataToTime:
      2026-09-22T11:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1925-07-08T11:00:00Z
      dataToTime:
      2026-09-21T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.