Tingvatn (Lygne)

Hydrological station 24.9.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-20T10:12:26Z.

Station and available series

stationId:
24.9.0
stationName:
Tingvatn (Lygne)
latitude:
58.40114
longitude:
7.22335
utmEast_Z33:
46112
utmNorth_Z33:
6499670
masl:
185
riverName:
Lygna
councilNumber:
4226
councilName:
Hægebostad
countyName:
Agder
drainageBasinKey:
861
hierarchy:
Lygna
lakeArea:
0
lakeName:
not reported by source
lakeNo:
1232
regineNo:
024.C1
reservoirNo:
not reported by source
reservoirName:
not reported by source
stationTypeName:
Forvaltningsstasjon
stationStatusName:
Aktiv
drainageBasinArea:
272.16
drainageBasinAreaNorway:
272.16
gradient1085:
12.18
gradientBasin:
27.31
gradientRiver:
14.82
heightMinimum:
183
heightHypso10:
388
heightHypso20:
490
heightHypso30:
590
heightHypso40:
619
heightHypso50:
640
heightHypso60:
665
heightHypso70:
723
heightHypso80:
759
heightHypso90:
833
heightMaximum:
963
lengthKmBasin:
30.74
lengthKmRiver:
43.12
percentAgricul:
1.24
percentBog:
6.32
percentEffBog:
not reported by source
percentEffLake:
3.12
percentForest:
40.97
percentGlacier:
0
percentLake:
9.75
percentMountain:
35.33
percentUrban:
0.05
utmZoneGravi:
33
utmEastGravi:
45718
utmNorthGravi:
6515544
utmZoneInlet:
33
utmEastInlet:
48530
utmNorthInlet:
6528898
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
525.61
specificDischarge:
61.19
regulationArea:
0
areaReservoirs:
0
volumeReservoirs:
0
regulationPartReservoirs:
0
transferAreaIn:
0
transferAreaOut:
0
reservoirAreaIn:
0
reservoirAreaOut:
0
reservoirVolumeIn:
0
reservoirVolumeOut:
0
remainingArea:
0
numberReservoirs:
0
firstYearRegulation:
0
catchmentRegTypeName:
Uregulert
owner:
HH. Hydrologisk avd./Hydrometri
qNumberOfYears:
102
qStartYear:
1923
qEndYear:
2025
qm:
102.0668
q5:
119.9219
q10:
135.7198
q20:
151.4199
q50:
172.5674
hm:
2.0273
h5:
2.2157
h10:
2.3737
h20:
2.5241
h50:
2.7177
culQm:
108.0928
culQ5:
127.0021
culQ10:
143.7327
culQ20:
160.3597
culQ50:
182.7558
culHm:
2.0921
culH5:
2.2874
culH10:
2.4513
culH20:
2.6071
culH50:
2.8077
seriesList:

5 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    1
    unit:
    m
    serieFrom:
    1994-10-14T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T17:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-19T11:00:00Z
  2. parameterName:
    Vannføring
    parameter:
    1001
    versionNo:
    1
    unit:
    m³/s
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T17:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-19T11:00:00Z
  3. parameterName:
    Vanntemperatur
    parameter:
    1003
    versionNo:
    1
    unit:
    °C
    serieFrom:
    2024-05-15T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      2024-07-30T16:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    2. resTime:
      60
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      2024-07-30T16:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    3. resTime:
      1440
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      2024-07-31T11:00:00Z
      dataToTime:
      2026-09-20T11:00:00Z
  4. parameterName:
    Magasinvolum
    parameter:
    1004
    versionNo:
    1
    unit:
    millioner m³
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T17:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-10-14T11:00:00Z
      dataToTime:
      2026-09-19T11:00:00Z
  5. parameterName:
    Lufttemperatur
    parameter:
    17
    versionNo:
    1
    unit:
    °C
    serieFrom:
    2004-06-16T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      2004-06-21T12:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2004-06-21T13:00:00Z
      dataToTime:
      2026-09-20T09:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2004-06-22T11:00:00Z
      dataToTime:
      2026-09-19T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.