Skyvatn

Hydrological station 21.42.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-21T11:20:32Z.

Station and available series

stationId:
21.42.0
stationName:
Skyvatn
latitude:
59.62793
longitude:
7.17402
utmEast_Z33:
59266
utmNorth_Z33:
6636006
masl:
1090
riverName:
Kaldsåi
councilNumber:
4222
councilName:
Bykle
countyName:
Agder
drainageBasinKey:
818
hierarchy:
Kaldsåi/Otra
lakeArea:
4.39
lakeName:
Skyvatn
lakeNo:
1077
regineNo:
021.LE
reservoirNo:
294
reservoirName:
SKYVATN
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
11.57
drainageBasinAreaNorway:
11.57
gradient1085:
0
gradientBasin:
20.44
gradientRiver:
12.11
heightMinimum:
1090
heightHypso10:
1109
heightHypso20:
1119
heightHypso30:
1128
heightHypso40:
1146
heightHypso50:
1174
heightHypso60:
1185
heightHypso70:
1208
heightHypso80:
1232
heightHypso90:
1268
heightMaximum:
1405
lengthKmBasin:
5.75
lengthKmRiver:
5.94
percentAgricul:
0
percentBog:
0.72
percentEffBog:
not reported by source
percentEffLake:
38.02
percentForest:
0
percentGlacier:
0
percentLake:
38.7
percentMountain:
60.59
percentUrban:
0
utmZoneGravi:
33
utmEastGravi:
60262
utmNorthGravi:
6634892
utmZoneInlet:
33
utmEastInlet:
59278
utmNorthInlet:
6636067
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
19.84
specificDischarge:
54.34
regulationArea:
11.57
areaReservoirs:
5.2
volumeReservoirs:
50.6
regulationPartReservoirs:
2.55
transferAreaIn:
3.37
transferAreaOut:
0
reservoirAreaIn:
0
reservoirAreaOut:
5.2
reservoirVolumeIn:
0
reservoirVolumeOut:
50.6
remainingArea:
0
numberReservoirs:
1
firstYearRegulation:
1981
catchmentRegTypeName:
Regulert m/magasinregulering og overføringer
owner:
Å ENERGI VANNKRAFT AS
qNumberOfYears:
not reported by source
qStartYear:
not reported by source
qEndYear:
not reported by source
qm:
not reported by source
q5:
not reported by source
q10:
not reported by source
q20:
not reported by source
q50:
not reported by source
hm:
not reported by source
h5:
not reported by source
h10:
not reported by source
h20:
not reported by source
h50:
not reported by source
culQm:
not reported by source
culQ5:
not reported by source
culQ10:
not reported by source
culQ20:
not reported by source
culQ50:
not reported by source
culHm:
not reported by source
culH5:
not reported by source
culH10:
not reported by source
culH20:
not reported by source
culH50:
not reported by source
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    50
    unit:
    m
    serieFrom:
    1994-06-20T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1994-06-20T11:00:00Z
      dataToTime:
      2026-06-20T22:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2003-12-31T13:00:00Z
      dataToTime:
      2026-06-20T22:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-06-20T11:00:00Z
      dataToTime:
      2026-06-20T11:00:00Z
  2. parameterName:
    Magasinvolum
    parameter:
    1004
    versionNo:
    50
    unit:
    millioner m³
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1994-06-20T11:00:00Z
      dataToTime:
      2026-06-20T22:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2003-12-31T13:00:00Z
      dataToTime:
      2026-06-20T22:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1994-06-20T11:00:00Z
      dataToTime:
      2026-06-20T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.