Finndøla

Hydrological station 19.63.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-21T16:11:04Z.

Station and available series

stationId:
19.63.0
stationName:
Finndøla
latitude:
59.22968
longitude:
8.07686
utmEast_Z33:
105361
utmNorth_Z33:
6586151
masl:
293
riverName:
Fyresdalsåna
councilNumber:
4032
councilName:
Fyresdal
countyName:
Telemark
drainageBasinKey:
742
hierarchy:
Fyresdalsåna/Arendalsvassdraget
lakeArea:
0
lakeName:
not reported by source
lakeNo:
0
regineNo:
019.DD21
reservoirNo:
not reported by source
reservoirName:
not reported by source
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
387.965
drainageBasinAreaNorway:
387.965
gradient1085:
11.94
gradientBasin:
24.72
gradientRiver:
12.79
heightMinimum:
293
heightHypso10:
683
heightHypso20:
778
heightHypso30:
819
heightHypso40:
857
heightHypso50:
891
heightHypso60:
931
heightHypso70:
972
heightHypso80:
1027
heightHypso90:
1099
heightMaximum:
1276
lengthKmBasin:
29.39
lengthKmRiver:
46.91
percentAgricul:
0.22
percentBog:
5.09
percentEffBog:
not reported by source
percentEffLake:
0.71
percentForest:
57.72
percentGlacier:
0
percentLake:
11.77
percentMountain:
23.37
percentUrban:
0
utmZoneGravi:
33
utmEastGravi:
88842
utmNorthGravi:
6588650
utmZoneInlet:
33
utmEastInlet:
83600
utmNorthInlet:
6600349
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
396.48
specificDischarge:
32.4
regulationArea:
323.06
areaReservoirs:
19.2
volumeReservoirs:
232.2
regulationPartReservoirs:
0.59
transferAreaIn:
13.02
transferAreaOut:
322.1
reservoirAreaIn:
0
reservoirAreaOut:
18.66
reservoirVolumeIn:
0
reservoirVolumeOut:
232.2
remainingArea:
64.71
numberReservoirs:
8
firstYearRegulation:
1972
catchmentRegTypeName:
regulert m/magasin og uregulert restfelt
owner:
Å ENERGI VANNKRAFT AS
qNumberOfYears:
14
qStartYear:
2003
qEndYear:
2016
qm:
18.9515
q5:
24.3462
q10:
27.1608
q20:
29.3787
q50:
31.6835
hm:
1.1639
h5:
1.2889
h10:
1.3495
h20:
1.3955
h50:
1.4417
culQm:
24.509
culQ5:
31.4856
culQ10:
35.1256
culQ20:
37.994
culQ50:
40.9746
culHm:
1.2924
culH5:
1.4378
culH10:
1.5083
culH20:
1.5618
culH50:
1.6157
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    1
    unit:
    m
    serieFrom:
    1956-06-08T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1956-06-08T11:00:00Z
      dataToTime:
      2026-09-21T08:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1985-01-01T00:00:00Z
      dataToTime:
      2026-09-21T08:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1956-06-08T11:00:00Z
      dataToTime:
      2026-09-20T11:00:00Z
  2. parameterName:
    Vannføring
    parameter:
    1001
    versionNo:
    1
    unit:
    m³/s
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1956-06-08T11:00:00Z
      dataToTime:
      2026-09-21T08:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1985-01-01T00:00:00Z
      dataToTime:
      2026-09-21T08:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1956-06-08T11:00:00Z
      dataToTime:
      2026-09-20T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.