Andkilvatn

Hydrological station 166.3.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-21T23:06:55Z.

Station and available series

stationId:
166.3.0
stationName:
Andkilvatn
latitude:
67.3967
longitude:
15.70056
utmEast_Z33:
530047
utmNorth_Z33:
7475774
masl:
12
riverName:
Fagerbakkvassdraget
councilNumber:
1845
councilName:
Sørfold
countyName:
Nordland
drainageBasinKey:
1966
hierarchy:
Fagerbakkvassdraget
lakeArea:
0
lakeName:
not reported by source
lakeNo:
0
regineNo:
166.B2
reservoirNo:
not reported by source
reservoirName:
not reported by source
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
249.4
drainageBasinAreaNorway:
249.4
gradient1085:
27.84
gradientBasin:
27.88
gradientRiver:
23.77
heightMinimum:
1
heightHypso10:
370
heightHypso20:
713
heightHypso30:
787
heightHypso40:
846
heightHypso50:
907
heightHypso60:
957
heightHypso70:
993
heightHypso80:
1055
heightHypso90:
1135
heightMaximum:
1419
lengthKmBasin:
24.37
lengthKmRiver:
38.75
percentAgricul:
0.04
percentBog:
0.67
percentEffBog:
not reported by source
percentEffLake:
5.18
percentForest:
7.59
percentGlacier:
6.99
percentLake:
14.73
percentMountain:
66.6
percentUrban:
0
utmZoneGravi:
33
utmEastGravi:
539783
utmNorthGravi:
7471081
utmZoneInlet:
33
utmEastInlet:
545825
utmNorthInlet:
7469657
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
615.53
specificDischarge:
78.21
regulationArea:
178.29
areaReservoirs:
17.71
volumeReservoirs:
655.5
regulationPartReservoirs:
1.06
transferAreaIn:
55.57
transferAreaOut:
229.36
reservoirAreaIn:
0
reservoirAreaOut:
17.71
reservoirVolumeIn:
0
reservoirVolumeOut:
655.5
remainingArea:
71.11
numberReservoirs:
2
firstYearRegulation:
1968
catchmentRegTypeName:
regulert m/magasin og uregulert restfelt
owner:
SISO ENERGI AS
qNumberOfYears:
14
qStartYear:
2012
qEndYear:
2025
qm:
30.6534
q5:
38.2937
q10:
47.0452
q20:
56.6707
q50:
71.2084
hm:
1.7904
h5:
1.9
h10:
2.0208
h20:
2.1491
h50:
2.3355
culQm:
32.4926
culQ5:
40.5913
culQ10:
49.8679
culQ20:
60.071
culQ50:
75.4809
culHm:
1.8172
culH5:
1.9322
culH10:
2.0589
culH20:
2.1934
culH50:
2.3889
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    1
    unit:
    m
    serieFrom:
    1960-09-01T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1960-09-02T11:00:00Z
      dataToTime:
      2026-09-21T22:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2012-05-23T11:00:00Z
      dataToTime:
      2026-09-21T22:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1960-09-01T11:00:00Z
      dataToTime:
      2026-09-21T11:00:00Z
  2. parameterName:
    Vannføring
    parameter:
    1001
    versionNo:
    1
    unit:
    m³/s
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1960-09-02T11:00:00Z
      dataToTime:
      2026-09-21T22:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      2012-05-23T11:00:00Z
      dataToTime:
      2026-09-21T22:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1960-09-01T11:00:00Z
      dataToTime:
      2026-09-21T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.