Rysna mvf.

Hydrological station 12.13.0.

Programmatic access to station metadata (JSON)

Source: NVE HydAPI. Retrieved 2026-09-22T01:37:50Z.

Station and available series

stationId:
12.13.0
stationName:
Rysna mvf.
latitude:
61.16853
longitude:
8.71596
utmEast_Z33:
162288
utmNorth_Z33:
6797807
masl:
615
riverName:
Rysna
councilNumber:
3454
councilName:
Vang
countyName:
Innlandet
drainageBasinKey:
392
hierarchy:
Rysna/Drammensvassdraget
lakeArea:
0
lakeName:
not reported by source
lakeNo:
0
regineNo:
012.NA
reservoirNo:
not reported by source
reservoirName:
not reported by source
stationTypeName:
Privat, pålagt
stationStatusName:
Aktiv
drainageBasinArea:
50.31
drainageBasinAreaNorway:
50.31
gradient1085:
63.02
gradientBasin:
27.09
gradientRiver:
53.92
heightMinimum:
614
heightHypso10:
882
heightHypso20:
1049
heightHypso30:
1169
heightHypso40:
1328
heightHypso50:
1452
heightHypso60:
1525
heightHypso70:
1587
heightHypso80:
1624
heightHypso90:
1641
heightMaximum:
1775
lengthKmBasin:
11.93
lengthKmRiver:
16.08
percentAgricul:
2.41
percentBog:
2.91
percentEffBog:
not reported by source
percentEffLake:
0.87
percentForest:
8.53
percentGlacier:
0
percentLake:
5.7
percentMountain:
75.69
percentUrban:
0
utmZoneGravi:
33
utmEastGravi:
158670
utmNorthGravi:
6802874
utmZoneInlet:
33
utmEastInlet:
154234
utmNorthInlet:
6805803
utmZoneOutlet:
not reported by source
utmEastOutlet:
not reported by source
utmNorthOutlet:
not reported by source
annualRunoff:
39.8
specificDischarge:
25.07
regulationArea:
9.7
areaReservoirs:
2.16
volumeReservoirs:
36
regulationPartReservoirs:
0.9
transferAreaIn:
0
transferAreaOut:
9.7
reservoirAreaIn:
0
reservoirAreaOut:
2.16
reservoirVolumeIn:
0
reservoirVolumeOut:
36
remainingArea:
40.61
numberReservoirs:
1
firstYearRegulation:
1967
catchmentRegTypeName:
regulert m/magasin og uregulert restfelt
owner:
FORENINGEN TIL BÆGNAVASSDRAGETS REGULERING
qNumberOfYears:
27
qStartYear:
1991
qEndYear:
2017
qm:
16.2904
q5:
20.4052
q10:
22.0541
q20:
23.2071
q50:
24.2566
hm:
615.4995
h5:
615.67
h10:
615.7327
h20:
615.775
h50:
615.8125
culQm:
24.6794
culQ5:
30.3076
culQ10:
32.4214
culQ20:
33.8841
culQ50:
35.4165
culHm:
615.8273
culH5:
616.0123
culH10:
616.0767
culH20:
616.1198
culH50:
616.1639
seriesList:

2 results

  1. parameterName:
    Vannstand
    parameter:
    1000
    versionNo:
    1
    unit:
    m
    serieFrom:
    1973-10-30T00:00:00
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1973-10-30T08:00:00Z
      dataToTime:
      2025-12-05T07:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1973-10-30T09:00:00Z
      dataToTime:
      2025-12-05T07:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1973-10-30T11:00:00Z
      dataToTime:
      2025-12-04T11:00:00Z
  2. parameterName:
    Vannføring
    parameter:
    1001
    versionNo:
    1
    unit:
    m³/s
    serieFrom:
    not reported by source
    serieTo:
    not reported by source
    resolutionList:

    3 results

    1. resTime:
      0
      method:
      Instantaneous
      timeOffset:
      0
      dataFromTime:
      1973-10-30T08:00:00Z
      dataToTime:
      2025-12-05T07:00:00Z
    2. resTime:
      60
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1973-10-30T09:00:00Z
      dataToTime:
      2025-12-05T07:00:00Z
    3. resTime:
      1440
      method:
      Mean
      timeOffset:
      0
      dataFromTime:
      1973-10-30T11:00:00Z
      dataToTime:
      2025-12-04T11:00:00Z

Fetch observations

Select parameter, resolution and time range

Continue exploring

How an AI agent should use this page

Ground rule: Navigate with HTML GET links to keep explanations and relationships. Use the page's JSON alternative only when concrete values must be extracted, compared or computed.

How to use the NVE station

Choose the right parameter ID, unit, resolution and reference period. Water level and discharge are different series and must not be mixed.