{"source":"doffin","operation":"search_doffin","parameters":{"query":"OSLO TECHNICAL SERVICE AS","limit":25,"offset":0},"data":{"total_count":4,"hits":[{"id":"2025-117112","buyer":[{"id":"b18742d32ea1485c6c315970580faa61","organization_id":"997058925","name":"OsloMet - storbyuniversitetet"}],"heading":"NGI-Modified Dynamic Cyclic Simple Shear (DSS) System","description":"Oslo Metropolitan University (OsloMet) intends to procure an NGI-Modified Dynamic Cyclic Simple Shear (DSS) System to support advanced teaching and research in geotechnical engineering. The system must meet the following technical, operational, educational and service requirements. We are not aware of any supplier other than the Norwegian Geotechnical Institute (NGI) that satisfies all the specifications listed below. If there are other suppliers capable of delivering equipment fulfilling these requirements, OsloMet kindly requests to be notified as soon as possible. The contract will not be signed earlier than 10 days after publication of this notice.\nThis i a one-off purchase. Total cost is around NOK         1, 430 000 millon e.g. VAT.\nThe procurement qualifies for a direct award without competition under FOA \u00a713-4(b) nr. 2 \u201ccompetition is impossible for technical reasons\u201d.\n\nFor mer informasjon se: https://hioa365-my.sharepoint.com/:w:/g/personal/annelins_oslomet_no/IQBe25zlHeacRq0qQrQmpOnCAcjG5WrafQcrTfr23iW_cwY?e=ofI2MM","location_id":["NO081"],"estimatedValue":null,"type":"ANNOUNCEMENT_OF_INTENT","allTypes":["ANNOUNCEMENT_OF_INTENT","RESULT"],"status":null,"issueDate":"2025-11-14T09:53:17Z","deadline":null,"sentToTed":true,"publicationDate":"2025-11-17","placeOfPerformance":["Oslo"],"procurementStrategicLabels":[]},{"id":"2019-334753","buyer":[{"id":"1172c118d3c0d86c04061c211258f772","organization_id":"985 198 292","name":"Avinor AS "}],"heading":"OSL Terminal Area Radar","description":"Terminal Area Radar Components of the scope of supply are intended to include: \u2022 Complete co-mounted primary and secondary radar system including pedestal and drive-train \u2022 Radome \u2022 Control and Monitoring functions \u2022 Necessary works for a good handover of a fully operational system \u2022 Options for maintenance of the system may be part of the scope of supply","location_id":[],"estimatedValue":null,"type":"ADVISORY_NOTICE","allTypes":["PLANNING","ADVISORY_NOTICE"],"status":null,"issueDate":"2019-01-08T10:00:00Z","deadline":null,"sentToTed":true,"publicationDate":"2019-01-08","placeOfPerformance":[],"procurementStrategicLabels":[]},{"id":"2025-119716","buyer":[{"id":"0f5223b4541cca6e7a1cfe09866c2ef9","organization_id":"971278374","name":"STATSBYGG"}],"heading":"1105601 UiO Livsvitenskap brukerutstyr - K930.22 MST instrument","description":"Statsbygg bygger det nye Livsvitenskapsbygget (LVB) for Universitetet i Oslo og Oslo universitetssykehus p\u00e5 oppdrag fra Kunnskapsdepartementet og Helse S\u00f8r-\u00d8st som medoppdragsgiver. Bygget skal v\u00e6re arbeidsplass for om lag 1.600 ansatte og 1.600 studenter. Oppstart for grave- og grunnarbeidene var 2. kvartal 2019 og planlagt ferdigstillelse er ultimo 2026. Her skal ulike fagmilj\u00f8er jobbe tverrfaglig for \u00e5 utvikle nye l\u00f8sninger p\u00e5 store utfordringer innen helse og b\u00e6rekraft med tilgang til det beste og mest moderne utstyret som kreves for \u00e5 drive forskning, undervisning og innovasjon i verdensklasse.Statsbygg intends to sign a contract with NanoTemper Technologies for the acquisition of a MST instrument, intrinsic tryptophan fluorescence, for the Life Sciences Building.We intend to purchase an MST instrument that is a capillary-based instrument for the analysis of molecular interactions using a combination of microscale thermophoresis (MST) and spectral shift with fluorescently labeled molecules as the principle of detection. The instrument must be an all-in-one, table-top model, and not exceed w400 x d600 x h550 mm in size due to space restrictions. The instrument must be able to measure both modalities in the same experiment on the same sample.We are researching, among other things, protein-protein and protein-ligand interactions, and the ability to analyze such interactions at equilibrium in a flow-free environment that does not require protein immobilization is a key feature that the equipment must satisfy. It is also essential that the system can measure many samples in series, in solution and with minimal use of material per sample. Through professional expertise in the laboratory, as well as research done online, we find that Monolith X is the only system with the following characteristics:Can do a combination of microscale thermophoresis (MST) and spectral shift with fluorescently labeled molecules as the principle of detection in the same instrument.Is an instrument that is an all-in-one, table-top model, not exceeding the size limitation.The Instrument can measure real-time changes in fluorescence intensity upon binding of ligand to the labeled protein while simultaneously changing the temperature of the sample (modality: microscale thermophoresis, MST).The instrument can measure real-time changes in fluorescence emission spectrum upon binding of ligand to the labeled protein as a result of a change in the fluorophore's emission spectrum (modality: spectral shift).The instrument can measure both modalities in the same experiment on the same sample.Can measure samples in very small volumes, using very small amounts of samples.\u00a0 See Appendix 4.0 Requirements MST Instrument K930.22 specification for more information on absolute requirements.Send an e-mail to kristine.milner.carlsen@statsbygg.no to receive the 4.0 Requirements MST Instrument K930.22 document. Summary:Given our technical requirements and needs, including in the attached requirement specification, the information we have and the investigations that have been carried out, to the best of our knowledge only Nanotemper technologies meets the requirements and can therefore, for technical reasons, deliver the service. The conditions in FOA \u00a7 13-4 (b) are deemed to be met.\u00a0Any objections must be reported via e-mail to kristine.milner.carlsen@statsbygg.no within 10 days of the published announcement.","location_id":["NO081"],"estimatedValue":null,"type":"ANNOUNCEMENT_OF_INTENT","allTypes":["ANNOUNCEMENT_OF_INTENT","RESULT"],"status":null,"issueDate":"2025-12-10T08:29:58Z","deadline":null,"sentToTed":true,"publicationDate":"2025-12-11","placeOfPerformance":["Oslo"],"procurementStrategicLabels":[]},{"id":"2025-119714","buyer":[{"id":"0f5223b4541cca6e7a1cfe09866c2ef9","organization_id":"971278374","name":"STATSBYGG"}],"heading":"1105601 UiO Livsvitenskap brukerutstyr - K930.22 DLS equipment proteinstabilitet","description":"Statsbygg bygger det nye Livsvitenskapsbygget (LVB) for Universitetet i Oslo og Oslo universitetssykehus p\u00e5 oppdrag fra Kunnskapsdepartementet og Helse S\u00f8r-\u00d8st som medoppdragsgiver. Bygget skal v\u00e6re arbeidsplass for om lag 1.600 ansatte og 1.600 studenter. Oppstart for grave- og grunnarbeidene var 2. kvartal 2019 og planlagt ferdigstillelse er ultimo 2026. Her skal ulike fagmilj\u00f8er jobbe tverrfaglig for \u00e5 utvikle nye l\u00f8sninger p\u00e5 store utfordringer innen helse og b\u00e6rekraft med tilgang til det beste og mest moderne utstyret som kreves for \u00e5 drive forskning, undervisning og innovasjon i verdensklasse.Statsbygg intends to sign a contract with NanoTemper Technologies for the acquisition of a DLS instrument, protein stability, for the Life Sciences Building.We intend to purchase a DLS instrument that is a capillary-based instrument for the analysis of protein stability, and protein aggregation using a combination of differential scanning fluorimetry (DSF), dynamic light scattering (DLS) and static light scattering (SLS) of native proteins as principles of detection. The instrument must be an all-in-one, table-top model, and not exceed w400 x d600 x h550 mm in size due to space restrictions. The instrument must be able to do the particle size analysis measurements simultaneously, immediately followed by the thermal analysis on the same sample in the same experiment.Among other things, we are researching the thermal stability of proteins and protein complexes, and the ability to analyze such samples at equilibrium in a flow-free environment that does not require immobilization, fluorescent labeling, or the use of external fluorescent reporters is a key function that the equipment must satisfy. It is also essential that the system can measure many samples in series, with high sensitivity, and with minimal use of material per sample.Through professional expertise in the laboratory, as well as research done online, we find that Prometheus Panta is the only system with the following characteristics:Can do differential scanning fluorimetry (DSF), dynamic light scattering (DLS) and static light scattering (SLS) of native proteins as principles of detection in the same instrument.Is an instrument that is an all-in-one, table-top model, not exceeding the size limitation.The instrument can do the particle size analysis measurements simultaneously, immediately followed by the thermal analysis on the same sample in the same experiment.Can measure samples in very small volumes, using very small amounts of samples.\u00a0See Appendix 4.0 Requirements DLS Equipment K930.22 specification for more information on absolute requirements.Send an e-mail to\u00a0kristine.milner.carlsen@statsbygg.no\u00a0to receive the Appendix 4.0 Requirements document.Summary:Given our technical requirements and needs, including in the attached requirement specification, the information we have and the investigations that have been carried out, to the best of our knowledge only Nanotemper technologies meets the requirements and can therefore, for technical reasons, deliver the service. The conditions in FOA \u00a7 13-4 (b) are deemed to be met.\u00a0Any objections must be reported via e-mail to\u00a0kristine.milner.carlsen@statsbygg.no\u00a0within 10 days of the published announcement.","location_id":["NO081"],"estimatedValue":null,"type":"ANNOUNCEMENT_OF_INTENT","allTypes":["ANNOUNCEMENT_OF_INTENT","RESULT"],"status":null,"issueDate":"2025-12-10T07:58:34Z","deadline":null,"sentToTed":true,"publicationDate":"2025-12-11","placeOfPerformance":["Oslo"],"procurementStrategicLabels":[]}],"limit":25,"offset":0,"returned":4,"has_more_results":false},"entities":[{"type":"procurement","id":"2025-117112","namespace":"doffin:notice","canonical_id":"doffin:notice:2025-117112","name":"NGI-Modified Dynamic Cyclic Simple Shear (DSS) System","description":"Oslo Metropolitan University (OsloMet) intends to procure an NGI-Modified Dynamic Cyclic Simple Shear (DSS) System to support advanced teaching and research in geotechnical engineering. The system must meet the following technical, operational, educational and service requirements. We are not aware of any supplier other than the Norwegian Geotechnical Institute (NGI) that satisfies all the specifications listed below. If there are other suppliers capable of delivering equipment fulfilling these requirements, OsloMet kindly requests to be notified as soon as possible. The contract will not be signed earlier than 10 days after publication of this notice.\nThis i a one-off purchase. Total cost is around NOK         1, 430 000 millon e.g. VAT.\nThe procurement qualifies for a direct award without competition under FOA \u00a713-4(b) nr. 2 \u201ccompetition is impossible for technical reasons\u201d.\n\nFor mer informasjon se: https://hioa365-my.sharepoint.com/:w:/g/personal/annelins_oslomet_no/IQBe25zlHeacRq0qQrQmpOnCAcjG5WrafQcrTfr23iW_cwY?e=ofI2MM","source":"doffin","attributes":{"status":null},"relationships":[{"type":"buyer","target":{"type":"organization","id":"997058925","namespace":"no:orgnr","canonical_id":"no:orgnr:997058925","name":"OsloMet - storbyuniversitetet"}}],"_links":{"wiki":"https://allemannsdata.com/wiki/anskaffelse/2025-117112/","api":"https://allemannsdata.com/wiki/api/v1/anskaffelser/2025-117112"}},{"type":"organization","id":"997058925","namespace":"no:orgnr","canonical_id":"no:orgnr:997058925","name":"OsloMet - storbyuniversitetet","description":"Buyer linked from the procurement notice.","source":"doffin","_links":{"wiki":"https://allemannsdata.com/wiki/selskap/997058925/","api":"https://allemannsdata.com/wiki/api/v1/selskaper/997058925"}},{"type":"procurement","id":"2019-334753","namespace":"doffin:notice","canonical_id":"doffin:notice:2019-334753","name":"OSL Terminal Area Radar","description":"Terminal Area Radar Components of the scope of supply are intended to include: \u2022 Complete co-mounted primary and secondary radar system including pedestal and drive-train \u2022 Radome \u2022 Control and Monitoring functions \u2022 Necessary works for a good handover of a fully operational system \u2022 Options for maintenance of the system may be part of the scope of supply","source":"doffin","attributes":{"status":null},"relationships":[{"type":"buyer","target":{"type":"organization","id":"985 198 292","namespace":"no:orgnr","canonical_id":"no:orgnr:985 198 292","name":"Avinor AS "}}],"_links":{"wiki":"https://allemannsdata.com/wiki/anskaffelse/2019-334753/","api":"https://allemannsdata.com/wiki/api/v1/anskaffelser/2019-334753"}},{"type":"organization","id":"985 198 292","namespace":"no:orgnr","canonical_id":"no:orgnr:985 198 292","name":"Avinor AS ","description":"Buyer linked from the procurement notice.","source":"doffin","_links":{"wiki":"https://allemannsdata.com/wiki/selskap/985%20198%20292/","api":"https://allemannsdata.com/wiki/api/v1/selskaper/985%20198%20292"}},{"type":"procurement","id":"2025-119716","namespace":"doffin:notice","canonical_id":"doffin:notice:2025-119716","name":"1105601 UiO Livsvitenskap brukerutstyr - K930.22 MST instrument","description":"Statsbygg bygger det nye Livsvitenskapsbygget (LVB) for Universitetet i Oslo og Oslo universitetssykehus p\u00e5 oppdrag fra Kunnskapsdepartementet og Helse S\u00f8r-\u00d8st som medoppdragsgiver. Bygget skal v\u00e6re arbeidsplass for om lag 1.600 ansatte og 1.600 studenter. Oppstart for grave- og grunnarbeidene var 2. kvartal 2019 og planlagt ferdigstillelse er ultimo 2026. Her skal ulike fagmilj\u00f8er jobbe tverrfaglig for \u00e5 utvikle nye l\u00f8sninger p\u00e5 store utfordringer innen helse og b\u00e6rekraft med tilgang til det beste og mest moderne utstyret som kreves for \u00e5 drive forskning, undervisning og innovasjon i verdensklasse.Statsbygg intends to sign a contract with NanoTemper Technologies for the acquisition of a MST instrument, intrinsic tryptophan fluorescence, for the Life Sciences Building.We intend to purchase an MST instrument that is a capillary-based instrument for the analysis of molecular interactions using a combination of microscale thermophoresis (MST) and spectral shift with fluorescently labeled molecules as the principle of detection. The instrument must be an all-in-one, table-top model, and not exceed w400 x d600 x h550 mm in size due to space restrictions. The instrument must be able to measure both modalities in the same experiment on the same sample.We are researching, among other things, protein-protein and protein-ligand interactions, and the ability to analyze such interactions at equilibrium in a flow-free environment that does not require protein immobilization is a key feature that the equipment must satisfy. It is also essential that the system can measure many samples in series, in solution and with minimal use of material per sample. Through professional expertise in the laboratory, as well as research done online, we find that Monolith X is the only system with the following characteristics:Can do a combination of microscale thermophoresis (MST) and spectral shift with fluorescently labeled molecules as the principle of detection in the same instrument.Is an instrument that is an all-in-one, table-top model, not exceeding the size limitation.The Instrument can measure real-time changes in fluorescence intensity upon binding of ligand to the labeled protein while simultaneously changing the temperature of the sample (modality: microscale thermophoresis, MST).The instrument can measure real-time changes in fluorescence emission spectrum upon binding of ligand to the labeled protein as a result of a change in the fluorophore's emission spectrum (modality: spectral shift).The instrument can measure both modalities in the same experiment on the same sample.Can measure samples in very small volumes, using very small amounts of samples.\u00a0 See Appendix 4.0 Requirements MST Instrument K930.22 specification for more information on absolute requirements.Send an e-mail to kristine.milner.carlsen@statsbygg.no to receive the 4.0 Requirements MST Instrument K930.22 document. Summary:Given our technical requirements and needs, including in the attached requirement specification, the information we have and the investigations that have been carried out, to the best of our knowledge only Nanotemper technologies meets the requirements and can therefore, for technical reasons, deliver the service. The conditions in FOA \u00a7 13-4 (b) are deemed to be met.\u00a0Any objections must be reported via e-mail to kristine.milner.carlsen@statsbygg.no within 10 days of the published announcement.","source":"doffin","attributes":{"status":null},"relationships":[{"type":"buyer","target":{"type":"organization","id":"971278374","namespace":"no:orgnr","canonical_id":"no:orgnr:971278374","name":"STATSBYGG"}}],"_links":{"wiki":"https://allemannsdata.com/wiki/anskaffelse/2025-119716/","api":"https://allemannsdata.com/wiki/api/v1/anskaffelser/2025-119716"}},{"type":"organization","id":"971278374","namespace":"no:orgnr","canonical_id":"no:orgnr:971278374","name":"STATSBYGG","description":"Buyer linked from the procurement notice.","source":"doffin","_links":{"wiki":"https://allemannsdata.com/wiki/selskap/971278374/","api":"https://allemannsdata.com/wiki/api/v1/selskaper/971278374"}},{"type":"procurement","id":"2025-119714","namespace":"doffin:notice","canonical_id":"doffin:notice:2025-119714","name":"1105601 UiO Livsvitenskap brukerutstyr - K930.22 DLS equipment proteinstabilitet","description":"Statsbygg bygger det nye Livsvitenskapsbygget (LVB) for Universitetet i Oslo og Oslo universitetssykehus p\u00e5 oppdrag fra Kunnskapsdepartementet og Helse S\u00f8r-\u00d8st som medoppdragsgiver. Bygget skal v\u00e6re arbeidsplass for om lag 1.600 ansatte og 1.600 studenter. Oppstart for grave- og grunnarbeidene var 2. kvartal 2019 og planlagt ferdigstillelse er ultimo 2026. Her skal ulike fagmilj\u00f8er jobbe tverrfaglig for \u00e5 utvikle nye l\u00f8sninger p\u00e5 store utfordringer innen helse og b\u00e6rekraft med tilgang til det beste og mest moderne utstyret som kreves for \u00e5 drive forskning, undervisning og innovasjon i verdensklasse.Statsbygg intends to sign a contract with NanoTemper Technologies for the acquisition of a DLS instrument, protein stability, for the Life Sciences Building.We intend to purchase a DLS instrument that is a capillary-based instrument for the analysis of protein stability, and protein aggregation using a combination of differential scanning fluorimetry (DSF), dynamic light scattering (DLS) and static light scattering (SLS) of native proteins as principles of detection. The instrument must be an all-in-one, table-top model, and not exceed w400 x d600 x h550 mm in size due to space restrictions. The instrument must be able to do the particle size analysis measurements simultaneously, immediately followed by the thermal analysis on the same sample in the same experiment.Among other things, we are researching the thermal stability of proteins and protein complexes, and the ability to analyze such samples at equilibrium in a flow-free environment that does not require immobilization, fluorescent labeling, or the use of external fluorescent reporters is a key function that the equipment must satisfy. It is also essential that the system can measure many samples in series, with high sensitivity, and with minimal use of material per sample.Through professional expertise in the laboratory, as well as research done online, we find that Prometheus Panta is the only system with the following characteristics:Can do differential scanning fluorimetry (DSF), dynamic light scattering (DLS) and static light scattering (SLS) of native proteins as principles of detection in the same instrument.Is an instrument that is an all-in-one, table-top model, not exceeding the size limitation.The instrument can do the particle size analysis measurements simultaneously, immediately followed by the thermal analysis on the same sample in the same experiment.Can measure samples in very small volumes, using very small amounts of samples.\u00a0See Appendix 4.0 Requirements DLS Equipment K930.22 specification for more information on absolute requirements.Send an e-mail to\u00a0kristine.milner.carlsen@statsbygg.no\u00a0to receive the Appendix 4.0 Requirements document.Summary:Given our technical requirements and needs, including in the attached requirement specification, the information we have and the investigations that have been carried out, to the best of our knowledge only Nanotemper technologies meets the requirements and can therefore, for technical reasons, deliver the service. The conditions in FOA \u00a7 13-4 (b) are deemed to be met.\u00a0Any objections must be reported via e-mail to\u00a0kristine.milner.carlsen@statsbygg.no\u00a0within 10 days of the published announcement.","source":"doffin","attributes":{"status":null},"relationships":[{"type":"buyer","target":{"type":"organization","id":"971278374","namespace":"no:orgnr","canonical_id":"no:orgnr:971278374","name":"STATSBYGG"}}],"_links":{"wiki":"https://allemannsdata.com/wiki/anskaffelse/2025-119714/","api":"https://allemannsdata.com/wiki/api/v1/anskaffelser/2025-119714"}}],"_meta":{"retrieved_at":"2026-10-31T02:21:42Z","language":"en","content_languages":["en"],"sources":[{"id":"doffin","name":"Doffin and TED","description":"Search Norwegian and European public procurement, notices and CPV codes.","cache_ttl_seconds":60}],"cache":{"hit":false,"stored_at":"2026-10-31T02:21:42Z","expires_at":"2026-10-31T02:22:42Z","ttl_seconds":60,"remaining_ttl_seconds":60,"age_seconds":0,"scope":"process"},"result_count":4,"total_available":4,"requested_limit":25,"possibly_truncated":false,"pagination":{"limit":25,"offset":0,"returned":4,"has_more_results":false,"next_offset":null},"response_size_ceiling_bytes":65536,"response_size_ceiling_enforced":true},"_provenance":{"data":{"source":"doffin","source_api":"https://allemannsdata.com/wiki/api/v1/kilder/doffin"},"entities":{"source":"doffin","source_api":"https://allemannsdata.com/wiki/api/v1/kilder/doffin","derived_from":"#/data","description":"Normalized projection of data."}},"_links":{"self":"https://allemannsdata.com/wiki/api/v1/kilder/doffin/search_doffin?offset=0&query=OSLO+TECHNICAL+SERVICE+AS","source":"https://allemannsdata.com/wiki/api/v1/kilder/doffin","wiki":"https://allemannsdata.com/wiki/kilder/doffin/search_doffin/?query=OSLO+TECHNICAL+SERVICE+AS&limit=25&offset=0","feedback":"https://allemannsdata.com/wiki/api/v1/feedback"},"output_fields":["total_count","hits","hits[].id","hits[].heading","hits[].description","hits[].buyer","hits[].buyer[].id","hits[].buyer[].organization_id","hits[].buyer[].name","hits[].type","hits[].allTypes","hits[].status","hits[].issueDate","hits[].deadline","hits[].publicationDate","hits[].sentToTed","hits[].estimatedValue","hits[].estimatedValue.currencyCode","hits[].estimatedValue.amount","hits[].location_id","hits[].placeOfPerformance","hits[].possible_placeholder","note","hits[].procurementStrategicLabels","limit","offset","returned","has_more_results"],"output_fields_truncated":false,"canonical_field_aliases":{"identifier":["hits[].id","hits[].buyer[].id"],"name":["hits[].heading","hits[].buyer[].name"]}}